Product Details:
Category:Outdoor SF6 Switchgear
Name:Pole Mount SF6 circuit breaker
Model:GKLW-12
Packing:Plastic bag & Wooden case or as requested
Delivery & Payment Terms:
Shipping time: Usually 30 days after the ordered confirmed
Payment:T/T, L/C, Western Union or Paypal
Trade term:FOB China port, or CIF
Environment condition
– Ambient temperature: -40℃~+40℃
– Altitude: ≤3000m
– Wind pressure: ≤700Pa(equals to wind speed 34m/s)
– Air contamination degree: IV degree
– Earthquake intensity: ≤8 degree
– Not be polluted by corrosive or flammable gas, vapor and salt-fog.
Feature
– Adopt insulated cable incoming and outgoing line, raise electrical gap and creepage distance;
– Install manual interlock device, to prevent misoperation while power failure;
– Overvoltage & undervoltage protection;
– Triple reclosing, local & remote switching control;
– To cut off rapidly the fault of unidirectional grounding, interphase short circuit within its boundaries
Technical Data
Rated voltage | kV | 12 | |||
Rated insulation level
(SF6 gas under 0.25Mpa, 20℃) |
Lightning impulse withstand voltage(full wave peak) | kV | 75 | ||
1min power frequency withstand voltage:
Phase to phase(earth)/fracture |
42/48 | ||||
Wet withstand voltage test | 34 | ||||
Reverse-phase impulse withstand voltage | 85 | ||||
insulation level
(SF6 gas under 0Mpa, 20℃) |
1min power frequency withstand voltage | kV | 30 | ||
1min reverse-phase withstand voltage | 30 | ||||
5min max. phase voltage | 9 | ||||
Rated current | A | 630 | |||
Rated breaking current | kA | 16 | 20 | ||
Breaking current under 0Mpa | A | 630 | |||
Mechanical life | Times | 6000 | |||
Rated operating sequence | Manual | (O)-180S-(CO)-180S-(CO) | |||
Motor | (O)-0.3S-(CO)-180S-(CO) | ||||
Rated closing current | kA | 40 | 50 | ||
Peak withstand current | kA | 40 | 50 | ||
Rated short time withstand current | kA | 16/4s | 20/4s | ||
Rated cable charging breaking current | A | 25 | |||
Rated line charging breaking current | A | 16 | |||
Contact total travel | mm | 58±2 | |||
Contact overtravel | mm | 22±1 | |||
Three phase synchronism (C-O) | mm | ≤1.5 | |||
Main loop resistance per phase (excluding cable) | μΩ | Terminal | ≤130 | ||
Cable | ≤650 | ||||
Inherent closing time | Motor | S | ≤0.06 | ||
Inherent opening time | Manual | S | ≤0.06 | ||
Motor | ≤0.04 | ||||
Yearly SF6 gas leakage | Year | ≤0.5% | |||
SF6 gas rated working pressure | MPa | 0.35(20℃) | |||
SF6 gas min. working pressure | MPa | 0.25(20℃) | |||
SF6 Weight | Manual | KG | 122 | ||
Motor | 130 | ||||
SF6 gas moisture content | ppm | ≤150 |